The Precision Boilers BD blowdown tank is used where there is ample space for a large tank to collect and hold boiler blowdown. The effluent sits in the tank until it has cooled below 140°F, and then it’s released into the facility drain. The portion of blowdown that flashes to steam can either be vented to atmosphere or recovered for use in preheating boiler feedwater.

Features & Benefits

  • Standard blowdown tank design pressure is 50 psi; the tank’s vent is sized to limit the vessel pressure to 5 psi
  • Boiler blowdown enters the vessel’s lower-pressure environment, where approx. 30% flashes to steam and then flows out the tank’s vent
  • Blowdown can be piped so that its latent heat is recovered and used to preheat boiler feedwater
  • Blowdown effluent is stored until its temperature falls below 140°F and a temperature controlled, self-operating valve opens to drain the tank
  • 30-1,200 gallons
Precision Boilers Model BD Manual
Have any questions? Give us a call.

Prefabricated Engineered Assemblies

We offer custom prefabricated engineered assemblies (packaged skids and enclosures) with the purchase of any boiler, heating, cooling or water system. Manufactured in the USA, these military-grade platforms deliver stability, portability, protection and a smaller footprint for large-scale industrial equipment.